| Параметр | Ценить |
|---|---|
| Note regarding axial connection technology:Only for stranded wires. The specified conductor cross sections refer to the geometric cross section of the cable used.Cables with a geometric cross section which deviates significantly from the nominal cable cross section must be checked before use.The axial connection technology connection space is designed for fine strand cables according to VDE 0295 Class 5. Deviating cable structures (e.g., Class 6 cables) must be checked before use.Assembly instructionsBefore assembly, ensure that the tapered screw is fully loosened (chamber is open). Cables must not be twisted. The wires must be pushed into the contact chamber as far as they will go (until the insulation touches the contact). Hold the wires in position and tighten using an Allen key. The used wire end must be cut off before reconnection. The terminal screw must only be retightened once to prevent the litz wires from breaking. To prevent damage to the contact, the wire/cable must be mechanically held at an appropriate distance from the connection point (e.g., when used in a plate cut out). For notes on correct execution, see DIN VDE 0100-520:2003-06. Unused connections must be tightened with maximum torque. | |
| Тип | D7 |
| Тесты | DIN VDE 0627/86 |
| Ширина | 21 mm |
| Высота | 34.8 mm |
| Длина | 21 mm |
| Ряд | HC-HS |
| Общий | for HC-D7 housing, axial connection 2.0 mm, Allen key |
| Приложение | Power |
| Тип продукта | Contact insert with a fixed no. of positions |
| Примечание по сборке | To ensure correct use, installation in housing with IP54 protection or better is required |
| Номинальный ток | 40 A |
| Пересмотр статьи | 04 |
| Диаметр контакта | 4 mm |
| Контактный материал | Copper alloy |
| Шестигранный гнездо | SW2,0 |
| Контактные номера | 1 - 2 |
| момент затяжки | 0.5 Nm ... 0.8 Nm (Mounting screws for mounting in the HEAVYCON housing) |
| Профиль подключения | 2+PE |
| Степень загрязнения | 3 |
| Габаритный чертеж | |
| Количество позиций | 2 |
| Номинальное импульсное напряжение | 6 kV |
| Категория перенапряжения | III |
| технология подключения | Axial screw connection |
| Тип контактного материала | turned |
| Количество силовых контактов | 2 |
| Номинальное напряжение (III/3) | 400 V |
| Поперечное сечение проводника | 4 mm² ... 10 mm² (The cross section specification refers to the geometric cross section of the cable used) |
| Контактный материал носителя | PC |
| Материал контактной поверхности | Ag |
| Циклы введения/извлечения | ≥ 500 |
| Сечение соединения AWG | 10 ... 8 |
| Температура окружающей среды (в рабочем режиме) | -40 °C ... 125 °C (including heating up of contacts) |
| Подключение в соответствии со стандартом | IEC / EN |
| Строительные и испытательные нормы | DIN VDE 0627/86 |
| Класс огнестойкости согласно UL 94 | V0 |
| Длина зачистки отдельного провода | 8 mm +1 mm |
Технические характеристики и данные о производительности