| Параметр | Ценить |
|---|---|
| Note regarding axial connection technology:Only for stranded wires. The conductor cross sections stated refer to the geometric cross section of the cable used.Use of cables with a geometric cross section very different from that of the cable's nominal cross section should be checked before use.The wiring space of the axial screw method is designed for fine strand cables according to VDE 0295 class 5. Deviating cable structures (e.g. class 6 cables) should be checked before use.ConnectionBefore starting to connect, ensure that the tapered screw is turned back all the way (chamber is open). The cables must not be twisted. The cores should be slid to the limit stop in the contact chamber (until insulation touches contact). Hold cores in position and use socket wrench to tighten. The used core end should be cut off before connecting again. The connection screw may only be retightened once to prevent the strands from breaking. To prevent damage to the contact, the core / cable should be mechanically intercepted at an appropriate distance from the connection point (e.g. by using a plate cutout). DIN VDE 0100-520:2003-06 contains information on how to do this correctly. | |
| Ширина | 34.2 mm |
| Высота | 40.6 mm |
| Длина | 14.6 mm |
| Ряд | HC-M-02 |
| Общий | For HEAVYCON housing type B6 to B48, HC-M-MHR... hinged retaining frame required |
| Приложение | Power |
| Тип продукта | Modular contact insert |
| Примечание по сборке | - Connection of the wires using a 2 mm Allen wrench.- Housing height ≥ 52 mm.- Axial screw connection only for flexible wires.- Plug-in connections may only be operated only when there is no load/voltage. |
| Номинальный ток | 40 A |
| Контактный материал | Copper alloy |
| Шестигранный гнездо | SW 2 |
| Контактные номера | 1 - 2 |
| момент затяжки | 1.5 Nm (2.5 mm² ... 4 mm²) |
| Профиль подключения | 2 |
| Степень загрязнения | 3 |
| Габаритный чертеж | |
| Количество позиций | 2 |
| Номинальное импульсное напряжение | 8 kV |
| Категория перенапряжения | III |
| технология подключения | Axial screw connection |
| Номинальное напряжение (III/3) | 1000 V |
| Количество слотов для модулей | 1 |
| Поперечное сечение проводника | 2.5 mm² ... 8 mm² (The cross section specification refers to the geometric cross section of the cable used) |
| Контактный материал носителя | PC |
| Материал контактной поверхности | Ag |
| Циклы введения/извлечения | ≥ 500 |
| Сечение соединения AWG | 12 ... 10 |
| Температура окружающей среды (в рабочем режиме) | -40 °C ... 125 °C |
| Подключение в соответствии со стандартом | IEC / EN |
| Класс огнестойкости согласно UL 94 | V0 |
| Длина зачистки отдельного провода | 8 mm +1 mm (for 6 mm²) |
Технические характеристики и данные о производительности