| Параметр | Ценить |
|---|---|
| Элемент | Specifications |
| Примечание | (Note:)measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20℃ +68℉. |
| Масса | Net weight: 30 g approx., Gross weight: 95 g approx. |
| Подробности | M12 connector type |
| Отображать | 4 digits + 4 digits 3-color LCD display (Display refresh rate: 250 ms, 500 ms, 1,000 ms, selectable by key operation) |
| Продукт | Dual Display Digital Pressure Sensor [For Gas] |
| Материал | Enclosure: PBT (glass fiber reinforced), LCD display: Acrylic, Pressure port: Stainless steel (SUS303) , Mounting threaded part: Brass (nickel plated), Switch part: Silicone rubber |
| Защита | IP40(IEC) |
| Аксессуары | Dedicated M12 connector cable, 0.3 m0.984 ftlong: 1 pc. |
| Номер детали | DP-101ZL3-M-P-C |
| Длина кабеля | Total length up to 20 m65.617 ft(Condition of CE compliance less than 20 m65.617 ft)is possible with 0.3 mm2, or more, cable. |
| Название продукта | Dual Display Digital Pressure Sensor [For Gas] DP-100L |
| порт давления | M5 female thread |
| Номер изделия | DP-101ZL3-M-P-C |
| Напряжение питания | 12 to 24 V DC ±10 % Ripple P-P 10 % or less |
| Влажность окружающей среды | 35 to 85 % RH, Storage: 35 to 85 % RH |
| Применимая жидкость | Non-corrosive gas |
| Выходной индикатор | Orange LED(Output operation indicator 1: Flashes during IO-Link communication, Lights up when the control output is ON during non-IO-Link communication (synchronized with the output operation indicator 2)Output operation indicator 2: Lights up when the control output is ON) |
| Ударопрочность | 100 m/s2acceleration (10 G approx.) in X, Y and Z directions three times each |
| Тип давления | Gauge pressure |
| Способ подключения | Connector |
| Потребление электроэнергии | Normal operation: 720 mW or less (Current consumption 30 mA or less at 24 V supply voltage)ECO mode: 480 mW or less at STD (Current consumption 20 mA or less at 24 V supply voltage)360 mW or less at FULL (Current consumption 15 mA or less at 24 V supply voltage) |
| Установите диапазон давления | -101.0 to +101.0kPa |
| Температура окружающей среды | -10 to +50℃+14 to +122 ℉(No dew condensation or icing allowed), Storage: -10 to +60℃+14 to +140 ℉ |
| Управляющий выход (DO) | PNP open-collector transistor•Maximum source current: 50 mA• Applied voltage: 30 V DC or less (between output and +V)• Residual voltage: 2 V or less (at 50 mA source current) |
| Номинальный диапазон давления | -100.0 to +100.0 kPa |
| Вибростойкость | 10 to 500 Hz frequency, 3 mm0.118 indouble amplitude or maximum acceleration 196 m/s2, in X, Y and Z directions for two hours each(when panel or flat attachment is mounted: 10 to 150 Hz frequency, 0.75 mm0.030 indouble amplitude or maximum acceleration 49 m/s2, in X, Y and Z directions for two hours each) |
| Сопротивление изоляции | 50 MΩ or more with 500 V DC megger between all supply terminals connected together and enclosure |
| Выдерживаемое напряжение | 1,000 V AC for one min. between all supply terminals connected together and enclosure |
| Выдерживаемость давления | 500kPa |
| Температурные характеристики | Within ±0.5 % F.S.(at +20℃+68℉) |
| Выход управления (DO): Гистерезис | Minimum 1 digit (variable) |
| Выходной сигнал управления (DO): Повторяемость | ±0.1 % F.S. (within ±2 digits) |
| Выходной сигнал управления (DO): Время отклика | 2.5 ms, 5 ms, 10 ms, 25 ms, 50 ms, 100 ms, 250 ms, 500 ms, 1,000 ms, 5,000 ms, selectable by key operation |
| Дисплей: отображаемый диапазон давления | -101.0 to +101.0 kPa |
| Выходной сигнал связи (C/Q): Скорость передачи данных | COM3 (230.4 kbps)(Note:)When the sensor is used as an ordinary sensor, the communication output (C/Q) provides the same output operation as the control output (DO). |
| Управляющий выход (DO): Работа выхода | N.O./N.C. (selectable by key operation) |
| Выходные данные коммуникации (C/Q): Данные процесса | 4 byte(Note:)When the sensor is used as an ordinary sensor, the communication output (C/Q) provides the same output operation as the control output (DO). |
| Соответствие нормативным требованиям и сертификация | CE Marking (EMC Directive, RoHS Directive), UKCA Marking (EMC Regulations, RoHS Regulations), UL/c-UL Certification |
| Управляющий выход (DO): Защита от короткого замыкания | Incorporated |
| Выходной сигнал связи (C/Q): Минимальное время цикла | 1.0ms(Note:)When the sensor is used as an ordinary sensor, the communication output (C/Q) provides the same output operation as the control output (DO). |
| Выходной сигнал связи (C/Q): связь IO-Link | IO-Link Specification V1.1(Note:)When the sensor is used as an ordinary sensor, the communication output (C/Q) provides the same output operation as the control output (DO). |
| Выход управления (DO): Режимы работы выхода | EASY mode / Hysteresis mode / Window comparator mode |
Технические характеристики и данные о производительности
Руководство по установке и эксплуатации