Основные характеристики
Элемент: Specifications
Кабель: 0.1 mm2, single core two parallel shielded cables, 2 m6.562 ftlong (Connector for amplifier attached)(Note) Cable cannot be extended.
Масса: Net weight: 30 g approxGross weight: 45 g approx
Подробности: Sensor head (Coaxial retroreflective type)
Информация о поставщике
PANASONIC
PANASONIC
Товары: 4316
Обычно отправка осуществляется в течение 2-3 рабочих дней.
Гарантия качества
Быстрая доставка
Техническая поддержка

Технические характеристики

Параметр Ценить
Элемент Specifications
Кабель 0.1 mm2, single core two parallel shielded cables, 2 m6.562 ftlong (Connector for amplifier attached)(Note) Cable cannot be extended.
Масса Net weight: 30 g approxGross weight: 45 g approx
Подробности Sensor head (Coaxial retroreflective type)
Продукт Digital Laser Sensor
Материал Enclosure: PBT (Mounting part: PEI)Lens cover: Acrylic
Аксессуар RF-330(Reflector): 1 pc.Warning label: 1 set(Labels are written in Japanese, English and Chinese for compliance with various standards.)
Защита IP40 (IEC)
Номер детали LS-H91
Название продукта Digital Laser Sensor LS-400
Номер изделия LS-H91
Влажность окружающей среды 35 to 85 % RH, Storage: 35 to 85 % RH
Ударопрочность 100 m/s2acceleration (10 G approx.) in X, Y and Z directions three times each
Окружающая освещенность Incandescent light: 3,000 lx or less at the light-receiving face
Температура окружающей среды -10 to +55 ℃+14 to +131 ℉(No dew condensation or icing allowed),Storage:-20 to +70 ℉
Индикатор работы Orange LED (lights up when the amplifier output is ON)
Регулятор формы пятна -
Вибростойкость 10 to 500 Hz frequency, 1.5 mm0.059 in(10 G max.) double amplitude in X, Y and Z directions for two hours each
Применимые усилители LS-401(P), LS-401(P)-C2, LS-403
Сопротивление изоляции 20 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure
Диапазон обнаружения: стандартный режим 0.1 to 5 m0.328 to16.404 ft(Note) The sensing range is the value for the RF-330 reflector. In addition, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.1 m0.328 ftaway. Note that if there are white papers or specular objects near the sensor head, reflected light from these objects may be received. In such cases, use the M.G.S. function of the amplifier unit to change the response time or incident light sensitivity.
Диапазон обнаружения: режим FAST 0.1 to 3 m0.328 to 9.843 ft(Note) The sensing range is the value for the RF-330 reflector. In addition, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.1 m0.328 ftaway. Note that if there are white papers or specular objects near the sensor head, reflected light from these objects may be received. In such cases, use the M.G.S. function of the amplifier unit to change the response time or incident light sensitivity.
Диапазон чувствительности: режим H-SP 0.1 to 3 m0.328 to 9.843 ft(Note) The sensing range is the value for the RF-330 reflector. In addition, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.1 m0.328 ftaway. Note that if there are white papers or specular objects near the sensor head, reflected light from these objects may be received. In such cases, use the M.G.S. function of the amplifier unit to change the response time or incident light sensitivity.
Диапазон обнаружения: режим U-LG 0.1 to 7 m0.328 to 22.966 ft(Note) The sensing range is the value for the RF-330 reflector. In addition, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.1 m0.328 ftaway. Note that if there are white papers or specular objects near the sensor head, reflected light from these objects may be received. In such cases, use the M.G.S. function of the amplifier unit to change the response time or incident light sensitivity.
Индикатор лазерного излучения Green LED (lights up during laser emission)
Выдерживаемое напряжение 1,000 V AC for one min.between all supply terminals connected together and enclosure
Соответствие директиве о маркировке CE. EMC Directive, RoHS Directive
Излучающий элемент: соответствует стандартам IEC / JIS / GB. Red semiconductor laser,Class 2 (IEC / JIS / GB)(Max. output: 3 mW Peak emission wavelength: 655 nm0.026 mil)
Излучающий элемент: соответствует стандартам FDA / IEC / JIS. Red semiconductor laser,Class 2 (FDA / IEC / JIS)(Max. output: 3 mW Peak emission wavelength: 655 nm 0.026 mil)(Note) This product complies with 21 CFR 1040.10 and 1040.11 Laser Notice No. 50, dated July 26, 2001, issued by CDRH (Center for Devices and Radiological Health) under the FDA (Food and Drug Administration). For details, refer to the Laser Notice No. 50.

Описание продукта

LS Series Digital Laser Sensor Head, Class 2, Coaxial Reflection on Mirror (7m)
Основные характеристики
  • Промышленное качество
  • Соответствует требованиям RoHS
  • Сертификат CE
  • Гарантия 1 год

Документация по продукту

Техническая спецификация

Технические характеристики и данные о производительности

Руководство пользователя

Руководство по установке и эксплуатации

Top