| Параметр | Ценить |
|---|---|
| Ue | |
| округ Колумбия | Resistive load (DC-12) |
| То есть | Main circuit, look monitor circuit |
| B10D | 2,000,000(ISO 13849-1 Annex C Table C.1) |
| Элемент | Specifications |
| Кабель | UL style 2464, No.22 AWG 12-core |
| Масса | Approx. 220 g |
| Подробности | Spring lock type |
| Продукт | Ultra-slim Safety door switch with solenoid interlock |
| Материал | Enclosure : PA66 |
| Защита | IP 67 (IEC 60529) |
| Номер детали | SG-B1-SB-G1 |
| Длина кабеля | 1m3.281 ft |
| Название продукта | Ultra-slim Safety door switch with solenoid interlock SG-B1 |
| Основные контакты | 1NC + 1NC |
| Номер изделия | SG-B1-SB-G1 |
| Сила блокировки | 500 N min. (GS-ET-19)(Note): The actuator locking strength is rated at 500 N of static load. Do not apply a load higher than the rated value.Do not apply a load higher than the rated value.When a higher load is expected to work on the actuator, provide an additional system consisting of another safety switch without lock (such as the SG-A1 safety switch) or a sensor to detect door opening and stop the machine. |
| Ударопрочность | Malfunction : 100 m/s2, Destruction : 1,000 m/s2 |
| Контактное сопротивление | 300 mΩ max. (initial value, 1 m3.281 ftcable)700 mΩ max. (initial value, 5 m16.404 ftcable) |
| Рабочая частота | 900 operations/hour |
| Применимые стандарты | EN 60947-5-1, GS-ET-19 |
| Сила прямого открытия | 60 N min. |
| Схема контроля двери | AC |
| Вибростойкость | Malfunction : 10 to 55 Hz, half amplitude 0.35 mm0.014 inDestruction : 30 Hz, half amplitude 1.5 mm0.059 in |
| Прямое открытие путешествий | 8 mm0.315 inmin. |
| Контакты датчика двери | 2NC |
| Электрическая долговечность | 100,000 operations min.(900 operations/hour,AC-12 125 V 2A, DC-12 125 V 0.4 A)1,000,000 operations min.(900 operations/hour,24 V AC/DC 0.1 A resistive load) |
| Контакты монитора блокировки | 1NO |
| Механическая прочность | 1,000,000 operations min. (GS-ET-19) |
| Тепловой ток (Ith) | ・Ambient temperature : -25 to +35 ℃-13 to +95 ℉2.5 A (up to 2 circuits)1.0 A (3 or more circuits)・Ambient temperature : 35 to +50 ℃95 to +122 ℉1.0 A (1 circuit)0.5 A (2 or more circuits) |
| Применимые правила | CE Marking [Machinery Directive (2006/42/EC), RoHS Directive], UKCA Marking [Supply of Machinery (Safety) Regulations (2008 No.1597), RoHS Regulations] |
| Индуктивная нагрузка (AC-15) | - |
| Индуктивная нагрузка (DC-13) | 1A |
| рабочая скорость привода | 0.05 to 1.0 m/sec. |
| Номинальное напряжение изоляции (Ui) | 300 V (Door monitor circuit)150 V (Main, Lock monitor circuit)30 V (Between ground and LED, solenoid circuit) |
| Условия эксплуатации: Высота над уровнем моря | 2,000 m6,561.68 ftmax. |
| класс защиты от поражения электрическим током | Class II (IEC 61140)(Note), 回(double insulated)(Note): Basic insulation of 2.5 kV, 1.5 kV impulse withstand voltage is ensured between different contact circuits and between contact circuits and LED or solenoid in the enclosure. When both SELV (safety extra low voltage) or PELV (protective extra low voltage) circuits and other circuits (such as 230 V AC circuits) are used for the solenoid power and contact circuits at the same time, the SELV or PELV requirements are not met any more. |
| Устройство защиты от короткого замыкания | Use 250 V / 10 A fast acting type fuse |
| Импульсное выдерживаемое напряжение (Uimp) | 2.5 kV (Door monitor circuit)1.5 kV (Main, Lock monitor circuit)0.5 kV (Between ground and LED, solenoid circuit) |
| Соленоид / Индикатор: Индикатор | Green LED |
| Соленоид / Индикатор: Номинальный ток | 110 mA (solenoid 100 mA, LED 10 mA : initial value) |
| Условия эксплуатации: влажность окружающей среды. | 45 to 85 % RH |
| Условия эксплуатации: Степень загрязнения | 3 (Inside 2) |
| Соленоид / Индикатор: Включение напряжения | Rated voltage × 85 % max. (at 20 ℃68 ℉) |
| Соленоид / Индикатор: Отключение напряжения | Rated voltage × 10 % min. (at 20 ℃68 ℉) |
| Применимые стандарты: Стандарты использования | IEC 60204-1 / EN 60204-1, ISO 14119, EN ISO 14119, IEC 60947-5-1, UL 508, CSA C22.2 No.14 |
| Условия эксплуатации: температура окружающей среды. | -25 to +50 ℃-13 to +122 ℉(No dew condensation or icing allowed)Storage : -40 to +80 ℃-40 to +176 ℉ |
| Соленоид / Индикатор: Номинальное рабочее напряжение | DC 24 V 100% duty cycle |
| Номинальное рабочее напряжение (Ue) / Номинальный рабочий ток (Ie) | Ue30V125V250VIeMain circuit, look monitor circuitACResistive load (AC-12)-2A-Inductive load (AC-15)-1A-DCResistive load (DC-12)2A0.4A-Inductive load (DC-13)1A0.22A-Door monitor circuitACResistive load (AC-12)-2.5A1.5AInductive load (AC-15)-1.5A0.75ADCResistive load (DC-12)2.5A1.1A0.55AInductive load (DC-13)2.3A0.55A0.27A |
Технические характеристики и данные о производительности